19" Wall Housing IP55, Depth 600 mm, RAL7035

19" Wall Housing IP55, 7U, Steel Door, Depth 600 mm, RAL7035
Item number: 691707IP55.2
EAN no.: 4049759156794
Get notified when the product is back in stock:
Piece

Enter your email in the field below and we will notify you when the product is back in stock.

Product information for 19" Wall Housing IP55, 7U, Steel Door, Depth 600 mm, RAL7035

Steel sheet housing with welded corpus, completely pre-assembled
Right- and left-sided metal covered air inlets for passive ventilation
Side walls not detachable
Roof hinged, inner roof prepared for mounting of Plug&Play fan unit Art.-No. 691656GR (cable not included, please order separately, e.g. Art.-No. EK504.x)
Bottom with PG glands 1 x PG48, 2 x PG21 and 3 x Ø 20 mm PVC blind grommets
For depth 450 mm inside 2 x 19" profile rails front-sided, galvanised, with numberung of rack units (U)
For depth 600 mm inside 4 x 19" profile rails (2 front, 2 rear), galvanised, with numberung of rack units (U)

Front door steel sheet with reinforcement and 3-point bar locking, lockable, with profile half-cylinder acc. to DIN 18252 / EN1303
Profile half-cylinder exchangeable by customer
Cabinet parts inside completely earthed
Max. load 100 kg
Paint finish RAL7035, light grey
Protection degree IP55
Plinth for use as standing cabinet available as option
Included accessories: 4 x Wall mount angle, 2 x key

Technical properties

Cabinet Series: 19" Wall Housing IP55
Cable entry roof/floor: Floor, PG glands 1 x PG48, 2 x PG21, 3 x Ø 20 mm PVC grommet
Degree of protection: IP55
Demountable: False
Door hinge reversible front door: No
Door opening angle front door: ca. 120 °
Frame: welded
Installation depth min. - max.: 530 mm
Material: Steel
Model: With permanent frame
Modular spacing: 482.6 mm (19 inch)
Mounting level: Front and rear
Number of cartons: 1
Number of doors: 1
PHC replaceable front door: Yes, DIN18252 (30/10 mm)
Packaging: 1 carton
Scope of delivery: 1x Cabinet, 4x wall mount, 2x keys
Structure/Use: Steel sheet housing with welded body, fully pre-assembled. PUR seals on roof and door for dust and water protection.
Surface finishing: powder coating
Type of front door: Steel door 1-part
Type of profile rail: L-shaped
Type of ventilation: Passive
With earthing: True
With front door: True
With roof plate: True
With sidewall: Yes, not openable

Variants

Item no. Name Depth Max. Load Color Width Height Number of height units RAL-number
691707IP55.2 19" Wall Housing IP55, 7U, Steel Door, Depth 600 mm, RAL7035 600 mm 100 kg grey 600 mm 410 mm 7 U 7035
691709IP55.2 19" Wall Housing IP55, 9U, Steel Door, Depth 600 mm, RAL7035 600 mm 100 kg grey 600 mm 500 mm 9 U 7035
691712IP55.2 19" Wall Housing IP55, 12U, Steel Door, Depth 600 mm, RAL7035 600 mm 100 kg grey 600 mm 630 mm 12 U 7035
691716IP55.2 19" Wall Housing IP55, 16U, Steel Door, Depth 600 mm, RAL7035 600 mm 100 kg grey 600 mm 810 mm 16 U 7035
691720IP55.2 19" Wall Housing IP55, 20U, Steel Door, Depth 600 mm, RAL7035 600 mm 100 kg grey 600 mm 1000 mm 20 U 7035

Safety instructions


Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly.

Manufacturer information


EFB-Elektronik GmbH   
Striegauer Straße 1   
33719 Bielefeld   
info@efb-elektronik.de    
https://www.efb-elektronik.de/kontakt