Data outlet Cat.6 250MHz, up/down, Flush, 2xRJ45, RAL9010
Product information for Data outlet Cat.6 250MHz, up/down, Flush, 2xRJ45, RAL9010
• Category 6 with 250 MHz bandwidth – Supports transmissions up to 5 Gb and creates reserves for structured network infrastructures.
• Dual shielded RJ45 with LSA connector – Allows for clean termination and contributes to stable signal quality.
• Flush-mounted mounting with cover frame, dust protection, text field and separate cable strain relief – facilitates professional integration and supports clear labelling and safe cable routing in everyday life.
The version is design-ready and has colour coding and a separate earthing connection. The shield connection is made via a screw. The supply cable for laying cables can be routed at the top or bottom. With its compact dimensions of 50 mm width, 50 mm height and 40.95 mm depth as well as protection class IP20, the data socket is suitable for structured cabling indoors.
Technical details
• Brand: EFB-Elektronik
• Category: 6
• Bandwidth: 250 MHz
• Transmission: 1 Gb, 2.5 Gb, 5 Gb
• Connector type: RJ45 2x8(8)
• Connection type: LSA
• With bushings/couplings: Yes
• Suitable for number of bushings/couplings: 2
• Sockets shielded: Yes
• Colour: white
• RAL number: 9010
• Mounting type shield connection: Screw
• Flush-mounted: Yes
• Floor tank/underfloor mounting: Yes
• Cover frame: Yes
• Outlet direction: oblique
• Mounting type: Screws
• With dust cover: Yes
• With text box: Yes
• Colour coding: Yes
• Designable: Yes
• Separate cable strain relief: Yes
• Separate ground connection: Yes
• Degree of protection (IP): IP20
• Installation cable feed: top/bottom
• Device width: 50 mm
• Device height: 50 mm
• Device depth: 40.95 mm
| Bandwidth: | 250 MHz |
|---|---|
| Category: | 6 |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Screw |
| Outlet direction: | Inclined |
| POE Standard: | POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
Technical properties
| Bandwidth: | 250 MHz |
|---|---|
| Category: | 6 |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Screw |
| Outlet direction: | Inclined |
| POE Standard: | POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
Variants
| Item no. | Name | Width of device | Depth of device | Supply line for installation cable | Height of device | Colour | |
|---|---|---|---|---|---|---|---|
| ET-25211.1V1 | Data outlet Cat.6 250MHz, up/down, Flush, 2xRJ45, RAL9010 | 50 mm | 40.95 mm | Up/down | 50 mm | white | |
| ET-25211.2V1 | Data outlet Cat.6 250MHz, right/left, Flush, 2xRJ45, RAL9010 | 50 mm | 40.95 mm | Left/right | 50 mm | white |
Product information for Data outlet Cat.6 250MHz, up/down, Flush, 2xRJ45, RAL9010
• Category 6 with 250 MHz bandwidth – Supports transmissions up to 5 Gb and creates reserves for structured network infrastructures.
• Dual shielded RJ45 with LSA connector – Allows for clean termination and contributes to stable signal quality.
• Flush-mounted mounting with cover frame, dust protection, text field and separate cable strain relief – facilitates professional integration and supports clear labelling and safe cable routing in everyday life.
The version is design-ready and has colour coding and a separate earthing connection. The shield connection is made via a screw. The supply cable for laying cables can be routed at the top or bottom. With its compact dimensions of 50 mm width, 50 mm height and 40.95 mm depth as well as protection class IP20, the data socket is suitable for structured cabling indoors.
Technical details
• Brand: EFB-Elektronik
• Category: 6
• Bandwidth: 250 MHz
• Transmission: 1 Gb, 2.5 Gb, 5 Gb
• Connector type: RJ45 2x8(8)
• Connection type: LSA
• With bushings/couplings: Yes
• Suitable for number of bushings/couplings: 2
• Sockets shielded: Yes
• Colour: white
• RAL number: 9010
• Mounting type shield connection: Screw
• Flush-mounted: Yes
• Floor tank/underfloor mounting: Yes
• Cover frame: Yes
• Outlet direction: oblique
• Mounting type: Screws
• With dust cover: Yes
• With text box: Yes
• Colour coding: Yes
• Designable: Yes
• Separate cable strain relief: Yes
• Separate ground connection: Yes
• Degree of protection (IP): IP20
• Installation cable feed: top/bottom
• Device width: 50 mm
• Device height: 50 mm
• Device depth: 40.95 mm
| Bandwidth: | 250 MHz |
|---|---|
| Category: | 6 |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Screw |
| Outlet direction: | Inclined |
| POE Standard: | POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
| Bandwidth: | 250 MHz |
|---|---|
| Category: | 6 |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Screw |
| Outlet direction: | Inclined |
| POE Standard: | POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
Variants
| Item no. | Name | Width of device | Depth of device | Supply line for installation cable | Height of device | Colour | |
|---|---|---|---|---|---|---|---|
| ET-25211.1V1 | Data outlet Cat.6 250MHz, up/down, Flush, 2xRJ45, RAL9010 | 50 mm | 40.95 mm | Up/down | 50 mm | white | |
| ET-25211.2V1 | Data outlet Cat.6 250MHz, right/left, Flush, 2xRJ45, RAL9010 | 50 mm | 40.95 mm | Left/right | 50 mm | white |
Safety instructions
Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse.
Manufacturer information