Data outlet Cat.6A 500MHz right/left, Flush, 2xRJ45, RAL9010
Product information for Data outlet Cat.6A 500MHz right/left, Flush, 2xRJ45, RAL9010
• Category 6A with 500 MHz bandwidth – Enables transmissions up to 10 Gbit and creates reserves for high-performance network infrastructures.
• Dual shielded RJ45 with LSA connector – Supports clean installation and contributes to stable signal quality.
• Flush-mounted mounting with dust protection, text field and cable strain relief – Facilitates professional integration and improves safe marking in everyday life.
The data socket is design-ready and has colour coding and a separate earthing connection. The shield connection is made via a terminal. The supply cable for laying cables can be routed on the left or right. With its compact dimensions of 50 mm width, 50 mm height and 40.95 mm depth as well as an IP20 protection class, the version is suitable for structured cabling indoors.
Technical details
• Brand: EFB-Elektronik
• Category: 6A (TIA)
• Bandwidth: 500 MHz
• Transmission: 1 Gb, 2.5 Gb, 5 Gb, 10 Gb
• Connector type: RJ45 2x8(8)
• Connection type: LSA
• With bushings/couplings: Yes
• Suitable for number of bushings/couplings: 2
• Sockets shielded: Yes
• Colour: white
• RAL number: 9010
• Mounting type shield connection: Clamp
• Flush-mounted: Yes
• Floor tank/underfloor mounting: Yes
• Cover frame: Yes
• Outlet direction: oblique
• Mounting type: Screws
• With dust cover: Yes
• With text box: Yes
• Colour coding: Yes
• Designable: Yes
• Separate cable strain relief: Yes
• Separate ground connection: Yes
• Degree of protection (IP): IP20
• Device width: 50 mm
• Device height: 50 mm
• Device depth: 40.95 mm
• Installation cable feed: left/right
| Bandwidth: | 500 MHz |
|---|---|
| Category: | 6A (TIA) |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Clamp |
| Outlet direction: | Inclined |
| POE Standard: | 4PPOE, POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit, 10 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
Technical properties
| Bandwidth: | 500 MHz |
|---|---|
| Category: | 6A (TIA) |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Clamp |
| Outlet direction: | Inclined |
| POE Standard: | 4PPOE, POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit, 10 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
Variants
| Item no. | Name | Supply line for installation cable | Width of device | Depth of device | Height of device | Colour | |
|---|---|---|---|---|---|---|---|
| ET-25130.1V1 | Data outlet Cat.6A 500MHz right/left, Flush, 2xRJ45, RAL9010 | Left/right | 50 mm | 40.95 mm | 50 mm | white | |
| ET-25133.1V1 | Data outlet Cat.6A 500MHz up/down, Flush, 2xRJ45, RAL9010 | Up/down | 50 mm | 40.95 mm | 50 mm | white |
Product information for Data outlet Cat.6A 500MHz right/left, Flush, 2xRJ45, RAL9010
• Category 6A with 500 MHz bandwidth – Enables transmissions up to 10 Gbit and creates reserves for high-performance network infrastructures.
• Dual shielded RJ45 with LSA connector – Supports clean installation and contributes to stable signal quality.
• Flush-mounted mounting with dust protection, text field and cable strain relief – Facilitates professional integration and improves safe marking in everyday life.
The data socket is design-ready and has colour coding and a separate earthing connection. The shield connection is made via a terminal. The supply cable for laying cables can be routed on the left or right. With its compact dimensions of 50 mm width, 50 mm height and 40.95 mm depth as well as an IP20 protection class, the version is suitable for structured cabling indoors.
Technical details
• Brand: EFB-Elektronik
• Category: 6A (TIA)
• Bandwidth: 500 MHz
• Transmission: 1 Gb, 2.5 Gb, 5 Gb, 10 Gb
• Connector type: RJ45 2x8(8)
• Connection type: LSA
• With bushings/couplings: Yes
• Suitable for number of bushings/couplings: 2
• Sockets shielded: Yes
• Colour: white
• RAL number: 9010
• Mounting type shield connection: Clamp
• Flush-mounted: Yes
• Floor tank/underfloor mounting: Yes
• Cover frame: Yes
• Outlet direction: oblique
• Mounting type: Screws
• With dust cover: Yes
• With text box: Yes
• Colour coding: Yes
• Designable: Yes
• Separate cable strain relief: Yes
• Separate ground connection: Yes
• Degree of protection (IP): IP20
• Device width: 50 mm
• Device height: 50 mm
• Device depth: 40.95 mm
• Installation cable feed: left/right
| Bandwidth: | 500 MHz |
|---|---|
| Category: | 6A (TIA) |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Clamp |
| Outlet direction: | Inclined |
| POE Standard: | 4PPOE, POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit, 10 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
| Bandwidth: | 500 MHz |
|---|---|
| Category: | 6A (TIA) |
| Centre plate: | True |
| Colour coding: | True |
| Connection type: | LSA |
| Cover frame: | True |
| Degree of protection: | IP20 |
| Design suitable: | True |
| Duct installation: | True |
| Floor box/sub-floor mounted: | True |
| Flush mounted (plaster): | True |
| Mounting method shielding connection: | Clamp |
| Outlet direction: | Inclined |
| POE Standard: | 4PPOE, POE+ |
| RAL-number: | 9010 |
| Separate earthing connection: | True |
| Separate strain relief: | True |
| Shielded buses: | True |
| Shielded housing: | True |
| Suitable for number of connectors: | 2 |
| Surface mounting: | False |
| Temperature Range (Operation): | -10 – 60 °C |
| Transmission: | 1 Gbit, 2,5 Gbit, 5 Gbit, 10 Gbit |
| Type of connector: | RJ45 2x8(8) |
| Type of fastening: | Screwing |
| With buses/couplings: | True |
| With dust cover: | True |
| With label space: | True |
Variants
| Item no. | Name | Supply line for installation cable | Width of device | Depth of device | Height of device | Colour | |
|---|---|---|---|---|---|---|---|
| ET-25130.1V1 | Data outlet Cat.6A 500MHz right/left, Flush, 2xRJ45, RAL9010 | Left/right | 50 mm | 40.95 mm | 50 mm | white | |
| ET-25133.1V1 | Data outlet Cat.6A 500MHz up/down, Flush, 2xRJ45, RAL9010 | Up/down | 50 mm | 40.95 mm | 50 mm | white |
Safety instructions
Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse.
Manufacturer information