Skip to main content Skip to search Skip to main navigation
Shopping cart

19" Network Cabinet PRO 24U, 800x1000 mm, RAL7035, Rear Door with Turning Handle

Product information for 19" Network Cabinet PRO 24U, 800x1000 mm, RAL7035, Rear Door with Turning Handle

The 19" network cabinet PRO-Advanced from the EFB-Elektronik brand with 24 U in 800 x 1000 mm and RAL 7035 is designed for demanding areas of application in the network and IT environment. It combines high mechanical stability with practical equipment for the structured installation of active and passive components.

• Load capacity up to 1,360 kg – Provides high reserves for heavy server, storage and network configurations.
• Safety glass front door and steel rear door – Allows visual inspection while providing robust protection of installed components.
• Passive ventilation, earthing and baying-compatible design – Supports safe operation and facilitates flexible expansion to the cabinet row.

The cabinet is designed for installations with increased space requirements and high cabling requirements. The passive ventilation works without active cooling and the cable entries in the roof and floor are each prepared with four pre-punched, break-out openings. In addition, the mounting levels at the front and rear, the front door made of 5 mm safety glass and the steel door at the rear ensure structured installation and practical maintenance. With protection class IP20 and earthing, the system is intended for use in protected indoor areas.

Technical details
• Number of doors: 2
• Degree of protection: IP20 according to EN 60529
• Type of ventilation: passive
• Air inlet floor: Break-out opening type A (380 x 380 mm), e.g. for filter or cable entry modules
• With earthing: Yes
• With roof panel: Yes
• With front door: Yes
• With side panels: Yes
• With rear door: Yes
• Mounting level: front and rear
• Front door design: one-piece glass door (certified safety glass, glass thickness 5 mm)
• Front door opening angle: 270°
• Rear door opening angle: 270°
• Front door locking: 1-point quarter-turn latch with swing handle
• Rear door locking: 1-point quarter-turn latch with swing handle
• Replaceable profile half-cylinder in front door: Yes, in accordance with DIN 18252 (30/10 mm)
• Scope of delivery: 1x cabinet, 1 x brush strip, 1 x cage nut set (pack of 20 pieces), earthing rail and earthing cable, 4 x levelling feet M12, 2 x keys
• Packaging: Delivered in transport packaging on a single-use pallet
Active air conditioning: False
Air inlet floor: Breakout opening type A (380 x 380 mm), e.g. for filter or cable entry modules
Cabinet Series: PRO
Cable entry roof/floor: Roof and base each with 4 pre-cut, breakable openings, all around, each 450 x 89 mm (re-sealable with a 19" 2U blanking plate)
Category: 19" network cabinet according to DIN41494
Degree of protection: IP20 according to EN60529
Demountable: True
Door hinge reversible front door: True
Door hinge reversible rear door: True
Door opening angle front door: 270 °
Door opening angle rear door: 270 °
Frame: screwed together, completely pre-assembled
Material: Steel
Model: With permanent frame
Modular spacing: 482.6 mm (19 inch)
Mounting level: Front and rear
PHC replaceable front door: True, according to DIN18252 (30/10 mm)
PHC replaceable rear door: True
Packaging: Delivery in transport packaging on a disposable pallet
Scope of delivery: 1x cabinet, 1 x brush strip, 1 x cage nut set (20 pieces per pack), grounding rail and grounding cable, 4 x M12 leveling feet, 2 x keys
Stackable: True
Surface finishing: Powder coating
Type of back door: Steel door 1-part
Type of front door: Glass door 1-part (certified safety glass, glass thickness 5 mm)
Type of profile rail: Crank
Type of ventilation: Passive
With backside door: True
With earthing: True
With front door: True
With roof plate: True
With sidewall: True
With socket: False

Technical properties

Active air conditioning: False
Air inlet floor: Breakout opening type A (380 x 380 mm), e.g. for filter or cable entry modules
Cabinet Series: PRO
Cable entry roof/floor: Roof and base each with 4 pre-cut, breakable openings, all around, each 450 x 89 mm (re-sealable with a 19" 2U blanking plate)
Category: 19" network cabinet according to DIN41494
Degree of protection: IP20 according to EN60529
Demountable: True
Door hinge reversible front door: True
Door hinge reversible rear door: True
Door opening angle front door: 270 °
Door opening angle rear door: 270 °
Frame: screwed together, completely pre-assembled
Material: Steel
Model: With permanent frame
Modular spacing: 482.6 mm (19 inch)
Mounting level: Front and rear
PHC replaceable front door: True, according to DIN18252 (30/10 mm)
PHC replaceable rear door: True
Packaging: Delivery in transport packaging on a disposable pallet
Scope of delivery: 1x cabinet, 1 x brush strip, 1 x cage nut set (20 pieces per pack), grounding rail and grounding cable, 4 x M12 leveling feet, 2 x keys
Stackable: True
Surface finishing: Powder coating
Type of back door: Steel door 1-part
Type of front door: Glass door 1-part (certified safety glass, glass thickness 5 mm)
Type of profile rail: Crank
Type of ventilation: Passive
With backside door: True
With earthing: True
With front door: True
With roof plate: True
With sidewall: True
With socket: False

Variants

Item no. Name Width Colour Rear door locking system With glazed door Front door locking system Number of height units Material rear door Max. load capacity Depth With vertical cable management Material front door Height RAL-number Number of doors
PRO-2480GR.G1S1 19" Network Cabinet PRO 24U, 800x1000 mm, RAL7035, Rear Door with Turning Handle 800 mm grey 1-point latch locking mechanism with swivel lever True 1-point latch locking mechanism with swivel lever 24 U Steel 1360 kg 1000 mm False Glass 1163 mm 7035 2
PRO-4280GR.G1S1 19" Network Cabinet PRO 42U, 800x1000 mm, RAL7035, Rear Door with Turning Handle 800 mm grey 3-point rod locking mechanism with swivel lever True 3-point rod locking mechanism with swivel lever 42 U Steel 1360 kg 1000 mm False Glass 1963 mm 7035 2

Product information for 19" Network Cabinet PRO 24U, 800x1000 mm, RAL7035, Rear Door with Turning Handle

The 19" network cabinet PRO-Advanced from the EFB-Elektronik brand with 24 U in 800 x 1000 mm and RAL 7035 is designed for demanding areas of application in the network and IT environment. It combines high mechanical stability with practical equipment for the structured installation of active and passive components.

• Load capacity up to 1,360 kg – Provides high reserves for heavy server, storage and network configurations.
• Safety glass front door and steel rear door – Allows visual inspection while providing robust protection of installed components.
• Passive ventilation, earthing and baying-compatible design – Supports safe operation and facilitates flexible expansion to the cabinet row.

The cabinet is designed for installations with increased space requirements and high cabling requirements. The passive ventilation works without active cooling and the cable entries in the roof and floor are each prepared with four pre-punched, break-out openings. In addition, the mounting levels at the front and rear, the front door made of 5 mm safety glass and the steel door at the rear ensure structured installation and practical maintenance. With protection class IP20 and earthing, the system is intended for use in protected indoor areas.

Technical details
• Number of doors: 2
• Degree of protection: IP20 according to EN 60529
• Type of ventilation: passive
• Air inlet floor: Break-out opening type A (380 x 380 mm), e.g. for filter or cable entry modules
• With earthing: Yes
• With roof panel: Yes
• With front door: Yes
• With side panels: Yes
• With rear door: Yes
• Mounting level: front and rear
• Front door design: one-piece glass door (certified safety glass, glass thickness 5 mm)
• Front door opening angle: 270°
• Rear door opening angle: 270°
• Front door locking: 1-point quarter-turn latch with swing handle
• Rear door locking: 1-point quarter-turn latch with swing handle
• Replaceable profile half-cylinder in front door: Yes, in accordance with DIN 18252 (30/10 mm)
• Scope of delivery: 1x cabinet, 1 x brush strip, 1 x cage nut set (pack of 20 pieces), earthing rail and earthing cable, 4 x levelling feet M12, 2 x keys
• Packaging: Delivered in transport packaging on a single-use pallet
Active air conditioning: False
Air inlet floor: Breakout opening type A (380 x 380 mm), e.g. for filter or cable entry modules
Cabinet Series: PRO
Cable entry roof/floor: Roof and base each with 4 pre-cut, breakable openings, all around, each 450 x 89 mm (re-sealable with a 19" 2U blanking plate)
Category: 19" network cabinet according to DIN41494
Degree of protection: IP20 according to EN60529
Demountable: True
Door hinge reversible front door: True
Door hinge reversible rear door: True
Door opening angle front door: 270 °
Door opening angle rear door: 270 °
Frame: screwed together, completely pre-assembled
Material: Steel
Model: With permanent frame
Modular spacing: 482.6 mm (19 inch)
Mounting level: Front and rear
PHC replaceable front door: True, according to DIN18252 (30/10 mm)
PHC replaceable rear door: True
Packaging: Delivery in transport packaging on a disposable pallet
Scope of delivery: 1x cabinet, 1 x brush strip, 1 x cage nut set (20 pieces per pack), grounding rail and grounding cable, 4 x M12 leveling feet, 2 x keys
Stackable: True
Surface finishing: Powder coating
Type of back door: Steel door 1-part
Type of front door: Glass door 1-part (certified safety glass, glass thickness 5 mm)
Type of profile rail: Crank
Type of ventilation: Passive
With backside door: True
With earthing: True
With front door: True
With roof plate: True
With sidewall: True
With socket: False

Active air conditioning: False
Air inlet floor: Breakout opening type A (380 x 380 mm), e.g. for filter or cable entry modules
Cabinet Series: PRO
Cable entry roof/floor: Roof and base each with 4 pre-cut, breakable openings, all around, each 450 x 89 mm (re-sealable with a 19" 2U blanking plate)
Category: 19" network cabinet according to DIN41494
Degree of protection: IP20 according to EN60529
Demountable: True
Door hinge reversible front door: True
Door hinge reversible rear door: True
Door opening angle front door: 270 °
Door opening angle rear door: 270 °
Frame: screwed together, completely pre-assembled
Material: Steel
Model: With permanent frame
Modular spacing: 482.6 mm (19 inch)
Mounting level: Front and rear
PHC replaceable front door: True, according to DIN18252 (30/10 mm)
PHC replaceable rear door: True
Packaging: Delivery in transport packaging on a disposable pallet
Scope of delivery: 1x cabinet, 1 x brush strip, 1 x cage nut set (20 pieces per pack), grounding rail and grounding cable, 4 x M12 leveling feet, 2 x keys
Stackable: True
Surface finishing: Powder coating
Type of back door: Steel door 1-part
Type of front door: Glass door 1-part (certified safety glass, glass thickness 5 mm)
Type of profile rail: Crank
Type of ventilation: Passive
With backside door: True
With earthing: True
With front door: True
With roof plate: True
With sidewall: True
With socket: False

Variants

Item no. Name Width Colour Rear door locking system With glazed door Front door locking system Number of height units Material rear door Max. load capacity Depth With vertical cable management Material front door Height RAL-number Number of doors
PRO-2480GR.G1S1 19" Network Cabinet PRO 24U, 800x1000 mm, RAL7035, Rear Door with Turning Handle 800 mm grey 1-point latch locking mechanism with swivel lever True 1-point latch locking mechanism with swivel lever 24 U Steel 1360 kg 1000 mm False Glass 1163 mm 7035 2
PRO-4280GR.G1S1 19" Network Cabinet PRO 42U, 800x1000 mm, RAL7035, Rear Door with Turning Handle 800 mm grey 3-point rod locking mechanism with swivel lever True 3-point rod locking mechanism with swivel lever 42 U Steel 1360 kg 1000 mm False Glass 1963 mm 7035 2

Safety instructions


Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range. Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse. Warning: Pay attention to the assembly sequence! Observe the correct assembly sequence, see instructions. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly. Warning: Do not exceed the load capacity! If the specified load capacity is exceeded, serious injuries may occur due to instability of the product.

Manufacturer information


EFB-Elektronik GmbH   
Striegauer Straße 1   
33719 Bielefeld   
info@efb-elektronik.de    
https://www.efb-elektronik.de/kontakt