Cat.7 Dätwyler 7702 862 MHz PIMF S/FTP
CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, yellow
Item number:
98713.1000
EAN no.:
4049759328191
Product information for CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, yellow
Cat.7 Dätwyler 7702 4P flex TC CPR Dca PIMF S/FTP
Electrically and mechanically excellent Cat.7 Patch cable- Exceeding the requirements of ISO/IEC 11801, IEC 61156-6, EN 50173-1 and EN50288-4-2. Excellent shielding due to pair and foil shielding. Copper wires and braiding tinned. Good assembly of connectors because of different wire colours. Compatible with all relevant connection systems of EN50173, ISO/IEC 11801 and IEC 60603-x. Flame retardance according to CPR Dca.
Use as a data patch cable or connection cable, special used for Consolidation points. Usable for all ICT Network application until Class F (600MHz) in accordance with EN50173-1 and ISO/IEC 11801. Also usable for Multimedia applications in CATV Frequence level till 862MHZ according to IEC15018. Suitable for data connection on power over ethernet (PoE/PoE+).
Electrically and mechanically excellent Cat.7 Patch cable- Exceeding the requirements of ISO/IEC 11801, IEC 61156-6, EN 50173-1 and EN50288-4-2. Excellent shielding due to pair and foil shielding. Copper wires and braiding tinned. Good assembly of connectors because of different wire colours. Compatible with all relevant connection systems of EN50173, ISO/IEC 11801 and IEC 60603-x. Flame retardance according to CPR Dca.
Use as a data patch cable or connection cable, special used for Consolidation points. Usable for all ICT Network application until Class F (600MHz) in accordance with EN50173-1 and ISO/IEC 11801. Also usable for Multimedia applications in CATV Frequence level till 862MHZ according to IEC15018. Suitable for data connection on power over ethernet (PoE/PoE+).
Technical properties
| AWG-size: | 26/7 |
|---|---|
| Bending radius (dynamic): | 40 mm |
| Bending radius (static): | 20 mm |
| Cable: | EN 50288-4-1 |
| Cable: | IEC 61156-6 |
| Cable structure: | S/FTP |
| Cabling standards: | ISO/IEC 11801 |
| Cabling standards: | EN 50173-1 |
| Category: | 7 |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 2 = stranded |
| Conductor material: | Cu, tinned |
| Core identification: | colour |
| Core insulation: | PVC |
| Delay skew: | 4 ns/100m |
| Flame retardant: | According to IEC/EN 60332-1-2 |
| Halogen free: | acc. EN 60754-1/2 |
| Halogen free (acc. EN 50267-2-2): | True |
| Installation standard: | EN 50174 |
| Jacket material: | FRNC-B |
| Loop resistance: | 275 Ohm/km |
| Low smoke: | acc. EN 61034 |
| Low smoke (acc. EN 61034-2): | True |
| Max. frequency: | 862 MHz |
| NVP value: | 78 % |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | 0 – 50 °C |
| PoE: | acc. to IEEE802.3af PoE |
| PoE: | acc. to IEEE802.3bt 4PPoE |
| PoE: | acc. to IEEE802.3at PoE+ |
| Resistance unbalance: | 3 % |
| Screen over stranding: | braiding |
| Screen over stranding element: | Foil |
| Stranding element: | Pairs |
| UV resistant: | no |
Variants
| Item no. | Name | Type | Number of cores | Length | Colour outer sheath | Copper weight | Weight | Max. tractive force | Outer diameter approx. | Fire load | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 98711.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, grey | simplex | 8 | 1000.0 m | grey | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98712.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, blue | simplex | 8 | 1000.0 m | blue | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98713.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, yellow | simplex | 8 | 1000.0 m | yellow | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98714.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, red | simplex | 8 | 1000.0 m | red | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98715.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, green | simplex | 8 | 1000.0 m | green | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98716.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, black | simplex | 8 | 1000.0 m | black | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98711.1 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, grey | simplex | 8 | 1.0 m | grey | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98712.1 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, blue | simplex | 8 | 1.0 m | blue | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98713.1 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, yellow | simplex | 8 | 1.0 m | yellow | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98714.1 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, red | simplex | 8 | 1.0 m | red | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98715.1 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, green | simplex | 8 | 1.0 m | green | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98716.1 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, black | simplex | 8 | 1.0 m | black | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m | |
| 98719.1000 | CU 7702 flex TC 4P AWG26/7 CPR Dca, Cat.7, 862MHz, orange | simplex | 8 | 1000.0 m | orange | 18.1 kg/km | 39.5 kg/km | 56 N | 5.8 mm | 0.38 MJ/m |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range.
Manufacturer information
Dätwyler IT Infra GmbH
Auf der Roos 4 - 12
65795 Hattersheim
info.itinfra.de@datwyler.com
https://itinfra.datwyler.com/de_de/