C-Profiles for Side-Mounting
Product information for C Profile Rail for Side Mounting, Cabinet Depth 600 mm
For side-mounting at the 19" profiles in EFB standing cabinets CLASSIC
For use in PRO series a slightly adjustment of 19" profile depth is necessary
Continuous 25 mm grid holes 11 x 7.3 mm
Material steel, galvanised
| Cabinet Series: | Universal |
|---|---|
| Material: | Steel |
| Model: | Profile rail |
| Scope of delivery: | 1 x Profile rail |
| Structure/Use: | C-profile rail with a slot width of 16 mm. For side mounting on 19" profile rails. Continuous perforation 7.3 x 11 mm in a 25 mm grid. |
Technical properties
| Cabinet Series: | Universal |
|---|---|
| Material: | Steel |
| Model: | Profile rail |
| Scope of delivery: | 1 x Profile rail |
| Structure/Use: | C-profile rail with a slot width of 16 mm. For side mounting on 19" profile rails. Continuous perforation 7.3 x 11 mm in a 25 mm grid. |
Variants
| Item no. | Name | Depth | Color | Suitable for enclosure building depth | Width | Height | For Cabinet Depth | |
|---|---|---|---|---|---|---|---|---|
| 691273.10V2 | C Profile Rail for Side Mounting, Cabinet Depth 1000 mm | 15 mm | metallic | 1000 mm | 775 mm | 30 mm | 1000 mm | |
| 691273.12V2 | C Profile Rail for Side Mounting, Cabinet Depth 1200 mm | 15 mm | metallic | 1200 mm | 975 mm | 30 mm | 1200 mm | |
| 691273.6V2 | C Profile Rail for Side Mounting, Cabinet Depth 600 mm | 15 mm | metallic | 600 mm | 375 mm | 30 mm | 600 mm | |
| 691273.8V2 | C Profile Rail for Side Mounting, Cabinet Depth 800 mm | 15 mm | metallic | 800 mm | 575 mm | 30 mm | 800 mm |
Product information for C Profile Rail for Side Mounting, Cabinet Depth 600 mm
For side-mounting at the 19" profiles in EFB standing cabinets CLASSIC
For use in PRO series a slightly adjustment of 19" profile depth is necessary
Continuous 25 mm grid holes 11 x 7.3 mm
Material steel, galvanised
| Cabinet Series: | Universal |
|---|---|
| Material: | Steel |
| Model: | Profile rail |
| Scope of delivery: | 1 x Profile rail |
| Structure/Use: | C-profile rail with a slot width of 16 mm. For side mounting on 19" profile rails. Continuous perforation 7.3 x 11 mm in a 25 mm grid. |
| Cabinet Series: | Universal |
|---|---|
| Material: | Steel |
| Model: | Profile rail |
| Scope of delivery: | 1 x Profile rail |
| Structure/Use: | C-profile rail with a slot width of 16 mm. For side mounting on 19" profile rails. Continuous perforation 7.3 x 11 mm in a 25 mm grid. |
Variants
| Item no. | Name | Depth | Color | Suitable for enclosure building depth | Width | Height | For Cabinet Depth | |
|---|---|---|---|---|---|---|---|---|
| 691273.10V2 | C Profile Rail for Side Mounting, Cabinet Depth 1000 mm | 15 mm | metallic | 1000 mm | 775 mm | 30 mm | 1000 mm | |
| 691273.12V2 | C Profile Rail for Side Mounting, Cabinet Depth 1200 mm | 15 mm | metallic | 1200 mm | 975 mm | 30 mm | 1200 mm | |
| 691273.6V2 | C Profile Rail for Side Mounting, Cabinet Depth 600 mm | 15 mm | metallic | 600 mm | 375 mm | 30 mm | 600 mm | |
| 691273.8V2 | C Profile Rail for Side Mounting, Cabinet Depth 800 mm | 15 mm | metallic | 800 mm | 575 mm | 30 mm | 800 mm |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range. Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Danger due to incorrect installation! Ensure that there are no loose objects in the danger zone. Assembly should be carried out by at least 2 people. Keep hands, hair and clothing away from moving parts. Warning: Pay attention to the assembly sequence! Observe the correct assembly sequence, see instructions. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly.
Manufacturer information