Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m
Content:
1 Stück
Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m
Item number:
99157.100
EAN no.:
8717511106771
Product information for Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m
The halogen-free Ethernet cable Cat.5e F/UTP in black from DRAKA is designed for high-performance network cabling. The F/UTP design with FRNC-B jacket supports stable data connections up to 300 MHz and is therefore suitable for modern installations with high bandwidth.
• 300 MHz Cat.5e bandwidth – Supports IEEE 802.3 from 10Mbit to 2.5Gbit, creating scope for high-performance networks.
• F/UTP design with foil shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in black – Is halogen-free according to EN 60754-1/2, complies with RoHS 2011/65/UE and adds a contemporary choice of materials to the installation.
The cable is designed as a simplex and uses 26/7 conductors with 8 wires. The dynamic bending radius of 40 mm facilitates installation. The foil shielding in the F/UTP structure supports decoupling from external influences. The design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt.
Technical details
• Brand: DRAKA
• Category: 5E
• Transmission standards: IEEE 802.3 10Mbit to 2.5Gbit
• Max. frequency: 300 MHz
• Cable construction: F/UTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 26/7
• Number of cores: 8
• Type: simplex
• Sheath material: FRNC-B
• Sheath colour: black
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: none
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: foil
• 300 MHz Cat.5e bandwidth – Supports IEEE 802.3 from 10Mbit to 2.5Gbit, creating scope for high-performance networks.
• F/UTP design with foil shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in black – Is halogen-free according to EN 60754-1/2, complies with RoHS 2011/65/UE and adds a contemporary choice of materials to the installation.
The cable is designed as a simplex and uses 26/7 conductors with 8 wires. The dynamic bending radius of 40 mm facilitates installation. The foil shielding in the F/UTP structure supports decoupling from external influences. The design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt.
Technical details
• Brand: DRAKA
• Category: 5E
• Transmission standards: IEEE 802.3 10Mbit to 2.5Gbit
• Max. frequency: 300 MHz
• Cable construction: F/UTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 26/7
• Number of cores: 8
• Type: simplex
• Sheath material: FRNC-B
• Sheath colour: black
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: none
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: foil
| AWG-size: | 26/7 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 300, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | F/UTP |
| Cable type: | Draka UC300 S26 |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 5e |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 2 = stranded |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Polyethylene (PE) |
| Coupling attenuation: | ≥ 55 dB |
| Diameter conductor: | 0.48 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | none |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 260 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 67 % |
| Nominal cross section conductor: | 0.16 mm² |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | 0 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | foil |
| Screen over stranding element: | without |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 2.5Gbit |
| UV resistant: | Nein |
Technical properties
| AWG-size: | 26/7 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 300, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | F/UTP |
| Cable type: | Draka UC300 S26 |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 5e |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 2 = stranded |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Polyethylene (PE) |
| Coupling attenuation: | ≥ 55 dB |
| Diameter conductor: | 0.48 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | none |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 260 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 67 % |
| Nominal cross section conductor: | 0.16 mm² |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | 0 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | foil |
| Screen over stranding element: | without |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 2.5Gbit |
| UV resistant: | Nein |
Variants
| Item no. | Name | Length | Type | Number of cores | Colour outer sheath | Copper weight | Weight | Max. tractive force | Outer diameter approx. | Fire load | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 99153.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, green | 1.0 m | simplex | 8 | green | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99153.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, gren | 1000.0 m | simplex | 8 | green | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99154.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue | 1.0 m | simplex | 8 | blue | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99154.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue | 1000.0 m | simplex | 8 | blue | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99155.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow | 1.0 m | simplex | 8 | yellow | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99155.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow | 1000.0 m | simplex | 8 | yellow | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99156.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, red | 1000.0 m | simplex | 8 | red | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99157.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m | 1.0 m | simplex | 8 | black | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99157.100 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m | 100.0 m | simplex | 8 | black | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99157.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black | 1000.0 m | simplex | 8 | black | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99158.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey | 1.0 m | simplex | 8 | grey | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99158.100 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey,100m | 100.0 m | simplex | 8 | grey | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99158.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey | 1000.0 m | simplex | 8 | grey | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km |
Product information for Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m
The halogen-free Ethernet cable Cat.5e F/UTP in black from DRAKA is designed for high-performance network cabling. The F/UTP design with FRNC-B jacket supports stable data connections up to 300 MHz and is therefore suitable for modern installations with high bandwidth.
• 300 MHz Cat.5e bandwidth – Supports IEEE 802.3 from 10Mbit to 2.5Gbit, creating scope for high-performance networks.
• F/UTP design with foil shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in black – Is halogen-free according to EN 60754-1/2, complies with RoHS 2011/65/UE and adds a contemporary choice of materials to the installation.
The cable is designed as a simplex and uses 26/7 conductors with 8 wires. The dynamic bending radius of 40 mm facilitates installation. The foil shielding in the F/UTP structure supports decoupling from external influences. The design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt.
Technical details
• Brand: DRAKA
• Category: 5E
• Transmission standards: IEEE 802.3 10Mbit to 2.5Gbit
• Max. frequency: 300 MHz
• Cable construction: F/UTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 26/7
• Number of cores: 8
• Type: simplex
• Sheath material: FRNC-B
• Sheath colour: black
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: none
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: foil
• 300 MHz Cat.5e bandwidth – Supports IEEE 802.3 from 10Mbit to 2.5Gbit, creating scope for high-performance networks.
• F/UTP design with foil shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in black – Is halogen-free according to EN 60754-1/2, complies with RoHS 2011/65/UE and adds a contemporary choice of materials to the installation.
The cable is designed as a simplex and uses 26/7 conductors with 8 wires. The dynamic bending radius of 40 mm facilitates installation. The foil shielding in the F/UTP structure supports decoupling from external influences. The design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt.
Technical details
• Brand: DRAKA
• Category: 5E
• Transmission standards: IEEE 802.3 10Mbit to 2.5Gbit
• Max. frequency: 300 MHz
• Cable construction: F/UTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 26/7
• Number of cores: 8
• Type: simplex
• Sheath material: FRNC-B
• Sheath colour: black
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: none
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: foil
| AWG-size: | 26/7 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 300, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | F/UTP |
| Cable type: | Draka UC300 S26 |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 5e |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 2 = stranded |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Polyethylene (PE) |
| Coupling attenuation: | ≥ 55 dB |
| Diameter conductor: | 0.48 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | none |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 260 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 67 % |
| Nominal cross section conductor: | 0.16 mm² |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | 0 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | foil |
| Screen over stranding element: | without |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 2.5Gbit |
| UV resistant: | Nein |
| AWG-size: | 26/7 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 300, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | F/UTP |
| Cable type: | Draka UC300 S26 |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 5e |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 2 = stranded |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Polyethylene (PE) |
| Coupling attenuation: | ≥ 55 dB |
| Diameter conductor: | 0.48 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | none |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 260 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 67 % |
| Nominal cross section conductor: | 0.16 mm² |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | 0 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | foil |
| Screen over stranding element: | without |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 2.5Gbit |
| UV resistant: | Nein |
Variants
| Item no. | Name | Length | Type | Number of cores | Colour outer sheath | Copper weight | Weight | Max. tractive force | Outer diameter approx. | Fire load | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 99153.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, green | 1.0 m | simplex | 8 | green | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99153.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, gren | 1000.0 m | simplex | 8 | green | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99154.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue | 1.0 m | simplex | 8 | blue | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99154.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue | 1000.0 m | simplex | 8 | blue | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99155.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow | 1.0 m | simplex | 8 | yellow | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99155.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow | 1000.0 m | simplex | 8 | yellow | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99156.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, red | 1000.0 m | simplex | 8 | red | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99157.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m | 1.0 m | simplex | 8 | black | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99157.100 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m | 100.0 m | simplex | 8 | black | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99157.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black | 1000.0 m | simplex | 8 | black | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99158.1 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey | 1.0 m | simplex | 8 | grey | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99158.100 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey,100m | 100.0 m | simplex | 8 | grey | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km | |
| 99158.1000 | Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey | 1000.0 m | simplex | 8 | grey | 12 kg/km | 26 kg/km | 55 N | 5.0 mm | 354 MJ/km |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range.
Manufacturer information
Draka Comteq Germany GmbH & Co. KG
Piccoloministraße 2
51063 Köln
kontakt@prysmian.com
https://de.prysmiangroup.com/