19" Cabinet IP55, 800 x 1000 mm, Side Cooling 1.0 - 1.9 kW

Product information for 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.9 kW

IP55 cabinet KS55-4280GR.x with side-mounted cooling solution
Protection degree of outer circulation area IP34
3 power levels 1.0, 1.5 and 1.9 kW cooling capacity
Cooling device for industrial purposes at high environmental temperatures up to +55°C
Industrial-qualified steel sheet housings
Compact, rugged design and simple function
Electromechanical thermostat and fault indicating contact
Integrated condensate evaporator
Temperature selection directly at the device
Optional exhaust air funnel allows the direct discharge of waste heat through an exhaust hose (⊘ 150 mm) from the installation room
Noise level 67 dB(A)
Power supply 230 V / 50 Hz
Supplied completely ready-for-installation including prepared cabinet with all openings, sealings, cables etc.
Alignment of cooling unit: Left
Function master/slave: False
Number of doors: 2
Sort of temperature control: Thermostat
Voltage type: AC

Technical properties

Alignment of cooling unit: Left
Function master/slave: False
Number of doors: 2
Sort of temperature control: Thermostat
Voltage type: AC

Variants

Item no. Name U With Air Funnel Ø 150 mm Cooling capacity, usable at 35 °C Width Height Depth Operating voltage at AC 50 Hz Operating voltage at AC 60 Hz
KS55-4280GR.1,0A 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.0 kW, exhaust funnel 42 True 1020 W 1037 mm 2144 mm 1000 mm 230 – V 230 – V
KS55-4280GR.1,9 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.9 kW 42 False 1960 W 1037 mm 2144 mm 1000 mm 230 – V 230 – V
KS55-4280GR.1,9A 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.9 kW, exhaust funnel 42 True 1960 W 1037 mm 2144 mm 1000 mm 230 – V 230 – V

Product information for 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.9 kW

IP55 cabinet KS55-4280GR.x with side-mounted cooling solution
Protection degree of outer circulation area IP34
3 power levels 1.0, 1.5 and 1.9 kW cooling capacity
Cooling device for industrial purposes at high environmental temperatures up to +55°C
Industrial-qualified steel sheet housings
Compact, rugged design and simple function
Electromechanical thermostat and fault indicating contact
Integrated condensate evaporator
Temperature selection directly at the device
Optional exhaust air funnel allows the direct discharge of waste heat through an exhaust hose (⊘ 150 mm) from the installation room
Noise level 67 dB(A)
Power supply 230 V / 50 Hz
Supplied completely ready-for-installation including prepared cabinet with all openings, sealings, cables etc.
Alignment of cooling unit: Left
Function master/slave: False
Number of doors: 2
Sort of temperature control: Thermostat
Voltage type: AC

Alignment of cooling unit: Left
Function master/slave: False
Number of doors: 2
Sort of temperature control: Thermostat
Voltage type: AC

Variants

Item no. Name U With Air Funnel Ø 150 mm Cooling capacity, usable at 35 °C Width Height Depth Operating voltage at AC 50 Hz Operating voltage at AC 60 Hz
KS55-4280GR.1,0A 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.0 kW, exhaust funnel 42 True 1020 W 1037 mm 2144 mm 1000 mm 230 – V 230 – V
KS55-4280GR.1,9 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.9 kW 42 False 1960 W 1037 mm 2144 mm 1000 mm 230 – V 230 – V
KS55-4280GR.1,9A 19" Cabinet, 42U, IP55, with IP34 Side Cooling 1.9 kW, exhaust funnel 42 True 1960 W 1037 mm 2144 mm 1000 mm 230 – V 230 – V

Safety instructions


Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Pay attention to the assembly sequence! Observe the correct assembly sequence, see instructions. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly. Warning: Do not exceed the load capacity! If the specified load capacity is exceeded, serious injuries may occur due to instability of the product.

Manufacturer information


EFB-Elektronik GmbH   
Striegauer Straße 1   
33719 Bielefeld   
info@efb-elektronik.de    
https://www.efb-elektronik.de/kontakt