19''Network Cabinet PEL 42HE 800x800 RAL7035 front glass 1-pc. rear steel 1-pc
Product information for 19''Network Cabinet PEL 42HE 800x800 RAL7035 front glass 1-pc. rear steel 1-pc
• 42U in 19-inch increments and 800 mm wide – Provides plenty of installation space for active and passive components while clearly structuring the mounting levels.
• Passive ventilation and cable entries in the roof and floor – Support a clean duct structure without active cooling.
• Pre-assembled, bolted frame with a load capacity of up to 800 kg – Facilitates installation and creates reserves for expansion.
The cabinet is designed for installations with increased space requirements and high wiring requirements. Passive ventilation supports operation in thermally non-critical environments, while the cable entries in the roof and floor as well as the rear door enable clean and adaptable cable routing. The mounting levels at the front and rear, the interchangeable door hinges and the robust design with glass door at the front and steel door at the rear keep access well organised for assembly and maintenance.
Technical details
• Number of doors: 2
• Degree of protection: IP20 according to EN 60529
• Type of ventilation: passive
• With earthing: Yes
• With roof panel: Yes
• With front door: Yes
• With side panels: Yes
• With rear door: Yes
• Mounting level: front and rear
• Front door design: one-piece glass door (certified safety glass, glass thickness 4 mm)
• Front door opening angle: 180 °
• Rear door opening angle: 180°
• Front door locking: 1-point quarter-turn latch with swing handle
• Rear door locking: 1-point quarter-turn latch
• Scope of delivery: 1x cabinet, 4 x levelling feet, cage nut set 40 pieces, wrench
• Packaging: Delivered in transport packaging on a single-use pallet
| Active air conditioning: | False |
|---|---|
| Cabinet Series: | PEL |
| Cable entry roof/floor: | Roof and base each 2 screwed openings (front, rear), each 386 x 69 mm (re-sealable with pre-mounted blanking plates) |
| Category: | 19" network cabinet according to DIN41494 |
| Degree of protection: | IP20 according to EN60529 |
| Demountable: | True |
| Door hinge reversible front door: | True |
| Door hinge reversible rear door: | True |
| Door opening angle front door: | 180 ° |
| Door opening angle rear door: | 180 ° |
| Frame: | screwed together, completely pre-assembled |
| Material: | Steel |
| Model: | With permanent frame |
| Modular spacing: | 482,6 mm (19 inch) |
| Mounting level: | Front and rear |
| PHC replaceable front door: | False, |
| PHC replaceable rear door: | False |
| Packaging: | Delivery in transport packaging on a disposable pallet |
| Scope of delivery: | 1x cabinet, 4 x leveling feet, cage nut set (20 pieces), key |
| Stackable: | True |
| Surface finishing: | Powder coating |
| Type of back door: | Steel door 1-part |
| Type of front door: | Glass door 1-part (certified safety glass, glass thickness 4 mm) |
| Type of profile rail: | Crank |
| Type of ventilation: | Passive |
| With backside door: | True |
| With earthing: | True |
| With front door: | True |
| With roof plate: | True |
| With sidewall: | True |
| With socket: | False |
Technical properties
| Active air conditioning: | False |
|---|---|
| Cabinet Series: | PEL |
| Cable entry roof/floor: | Roof and base each 2 screwed openings (front, rear), each 386 x 69 mm (re-sealable with pre-mounted blanking plates) |
| Category: | 19" network cabinet according to DIN41494 |
| Degree of protection: | IP20 according to EN60529 |
| Demountable: | True |
| Door hinge reversible front door: | True |
| Door hinge reversible rear door: | True |
| Door opening angle front door: | 180 ° |
| Door opening angle rear door: | 180 ° |
| Frame: | screwed together, completely pre-assembled |
| Material: | Steel |
| Model: | With permanent frame |
| Modular spacing: | 482,6 mm (19 inch) |
| Mounting level: | Front and rear |
| PHC replaceable front door: | False, |
| PHC replaceable rear door: | False |
| Packaging: | Delivery in transport packaging on a disposable pallet |
| Scope of delivery: | 1x cabinet, 4 x leveling feet, cage nut set (20 pieces), key |
| Stackable: | True |
| Surface finishing: | Powder coating |
| Type of back door: | Steel door 1-part |
| Type of front door: | Glass door 1-part (certified safety glass, glass thickness 4 mm) |
| Type of profile rail: | Crank |
| Type of ventilation: | Passive |
| With backside door: | True |
| With earthing: | True |
| With front door: | True |
| With roof plate: | True |
| With sidewall: | True |
| With socket: | False |
Variants
| Item no. | Name | Depth | Rear door locking system | Colour | Front door locking system | Width | Max. load capacity | Material rear door | With vertical cable management | Material front door | Number of height units | Height | RAL-number | Number of doors | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PEL-2466GR.G1SV | 19''Network Cabinet PEL 24HE 600x600 RAL7035 front glass 1-pc. rear steel 1-pc | 600 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 600 mm | 800 kg | Steel | False | Glass | 24 U | 1200 mm | 7035 | 2 | |
| PEL-4266GR.G1SV | 19''Network Cabinet PEL 42HE 600x600 RAL7035 front glass 1-pc. rear steel 1-pc | 600 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 600 mm | 800 kg | Steel | False | Glass | 42 HE | 2000 mm | 7035 | 2 | |
| PEL-4280GR.G1SV | 19''Network Cabinet PEL 42HE 800x1000 RAL7035 front glass 1-pc. rear steel 1-pc | 1000 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 800 mm | 800 kg | Steel | False | Glass | 42 HE | 2000 mm | 7035 | 2 | |
| PEL-4288GR.G1SV | 19''Network Cabinet PEL 42HE 800x800 RAL7035 front glass 1-pc. rear steel 1-pc | 800 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 800 mm | 800 kg | Steel | False | Glass | 42 HE | 2000 mm | 7035 | 2 |
Product information for 19''Network Cabinet PEL 42HE 800x800 RAL7035 front glass 1-pc. rear steel 1-pc
• 42U in 19-inch increments and 800 mm wide – Provides plenty of installation space for active and passive components while clearly structuring the mounting levels.
• Passive ventilation and cable entries in the roof and floor – Support a clean duct structure without active cooling.
• Pre-assembled, bolted frame with a load capacity of up to 800 kg – Facilitates installation and creates reserves for expansion.
The cabinet is designed for installations with increased space requirements and high wiring requirements. Passive ventilation supports operation in thermally non-critical environments, while the cable entries in the roof and floor as well as the rear door enable clean and adaptable cable routing. The mounting levels at the front and rear, the interchangeable door hinges and the robust design with glass door at the front and steel door at the rear keep access well organised for assembly and maintenance.
Technical details
• Number of doors: 2
• Degree of protection: IP20 according to EN 60529
• Type of ventilation: passive
• With earthing: Yes
• With roof panel: Yes
• With front door: Yes
• With side panels: Yes
• With rear door: Yes
• Mounting level: front and rear
• Front door design: one-piece glass door (certified safety glass, glass thickness 4 mm)
• Front door opening angle: 180 °
• Rear door opening angle: 180°
• Front door locking: 1-point quarter-turn latch with swing handle
• Rear door locking: 1-point quarter-turn latch
• Scope of delivery: 1x cabinet, 4 x levelling feet, cage nut set 40 pieces, wrench
• Packaging: Delivered in transport packaging on a single-use pallet
| Active air conditioning: | False |
|---|---|
| Cabinet Series: | PEL |
| Cable entry roof/floor: | Roof and base each 2 screwed openings (front, rear), each 386 x 69 mm (re-sealable with pre-mounted blanking plates) |
| Category: | 19" network cabinet according to DIN41494 |
| Degree of protection: | IP20 according to EN60529 |
| Demountable: | True |
| Door hinge reversible front door: | True |
| Door hinge reversible rear door: | True |
| Door opening angle front door: | 180 ° |
| Door opening angle rear door: | 180 ° |
| Frame: | screwed together, completely pre-assembled |
| Material: | Steel |
| Model: | With permanent frame |
| Modular spacing: | 482,6 mm (19 inch) |
| Mounting level: | Front and rear |
| PHC replaceable front door: | False, |
| PHC replaceable rear door: | False |
| Packaging: | Delivery in transport packaging on a disposable pallet |
| Scope of delivery: | 1x cabinet, 4 x leveling feet, cage nut set (20 pieces), key |
| Stackable: | True |
| Surface finishing: | Powder coating |
| Type of back door: | Steel door 1-part |
| Type of front door: | Glass door 1-part (certified safety glass, glass thickness 4 mm) |
| Type of profile rail: | Crank |
| Type of ventilation: | Passive |
| With backside door: | True |
| With earthing: | True |
| With front door: | True |
| With roof plate: | True |
| With sidewall: | True |
| With socket: | False |
| Active air conditioning: | False |
|---|---|
| Cabinet Series: | PEL |
| Cable entry roof/floor: | Roof and base each 2 screwed openings (front, rear), each 386 x 69 mm (re-sealable with pre-mounted blanking plates) |
| Category: | 19" network cabinet according to DIN41494 |
| Degree of protection: | IP20 according to EN60529 |
| Demountable: | True |
| Door hinge reversible front door: | True |
| Door hinge reversible rear door: | True |
| Door opening angle front door: | 180 ° |
| Door opening angle rear door: | 180 ° |
| Frame: | screwed together, completely pre-assembled |
| Material: | Steel |
| Model: | With permanent frame |
| Modular spacing: | 482,6 mm (19 inch) |
| Mounting level: | Front and rear |
| PHC replaceable front door: | False, |
| PHC replaceable rear door: | False |
| Packaging: | Delivery in transport packaging on a disposable pallet |
| Scope of delivery: | 1x cabinet, 4 x leveling feet, cage nut set (20 pieces), key |
| Stackable: | True |
| Surface finishing: | Powder coating |
| Type of back door: | Steel door 1-part |
| Type of front door: | Glass door 1-part (certified safety glass, glass thickness 4 mm) |
| Type of profile rail: | Crank |
| Type of ventilation: | Passive |
| With backside door: | True |
| With earthing: | True |
| With front door: | True |
| With roof plate: | True |
| With sidewall: | True |
| With socket: | False |
Variants
| Item no. | Name | Depth | Rear door locking system | Colour | Front door locking system | Width | Max. load capacity | Material rear door | With vertical cable management | Material front door | Number of height units | Height | RAL-number | Number of doors | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PEL-2466GR.G1SV | 19''Network Cabinet PEL 24HE 600x600 RAL7035 front glass 1-pc. rear steel 1-pc | 600 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 600 mm | 800 kg | Steel | False | Glass | 24 U | 1200 mm | 7035 | 2 | |
| PEL-4266GR.G1SV | 19''Network Cabinet PEL 42HE 600x600 RAL7035 front glass 1-pc. rear steel 1-pc | 600 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 600 mm | 800 kg | Steel | False | Glass | 42 HE | 2000 mm | 7035 | 2 | |
| PEL-4280GR.G1SV | 19''Network Cabinet PEL 42HE 800x1000 RAL7035 front glass 1-pc. rear steel 1-pc | 1000 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 800 mm | 800 kg | Steel | False | Glass | 42 HE | 2000 mm | 7035 | 2 | |
| PEL-4288GR.G1SV | 19''Network Cabinet PEL 42HE 800x800 RAL7035 front glass 1-pc. rear steel 1-pc | 800 mm | 1-point latch locking mechanism | grey | 1-point latch locking mechanism with swivel lever | 800 mm | 800 kg | Steel | False | Glass | 42 HE | 2000 mm | 7035 | 2 |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range. Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse. Warning: Pay attention to the assembly sequence! Observe the correct assembly sequence, see instructions. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly. Warning: Do not exceed the load capacity! If the specified load capacity is exceeded, serious injuries may occur due to instability of the product.
Manufacturer information