INFRALAN Cat.7 1000 AWG23 S/FTP 4P duplex CPR Cca
INFRALAN Cat.7 1000 AWG23 S/FTP 2x4P CPR Cca orange 100m
Item number:
99988DX.100-CPR
EAN no.:
4049759319045
Product information for INFRALAN Cat.7 1000 AWG23 S/FTP 2x4P CPR Cca orange 100m
The INFRALAN® installation cable is constructed for transmissions up to 1000 MHz and exceeds the requirements of the category 7 with the electrical transmission properties. With this cable transmission rates up to 10 GBit according to IEEE 802.3 are possible.
Technical properties
| AWG-size: | 23/1 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 60 mm |
| Bending radius (static): | ≥ 30 mm |
| Cable: |
EN 50288-4-1 1000 IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | S/FTP |
| Cable type: | EFB Cat.7A S/FTP 1000 AWG23 Cca |
| Cabling standards: |
EN 50173-1 ISO/IEC 11801 |
| Capacity to earth: | 43 pF/km |
| Category: | 7 |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 1 = solid |
| Conductor material: | Copper, bare |
| Core identification: | Colour |
| Core insulation: | Foam-Skin-PE |
| Coupling attenuation: | ≥ 80 dB |
| Delay skew: | ≤ 12 ns/100m |
| Diameter conductor: | 0.56 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | Cca |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Jacket material: | LSZH |
| Loop resistance: | 154 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Max. frequency: | MHz MHz |
| NVP value: | 79 % |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | 0 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: |
acc. to IEEE802.3af PoE acc. to IEEE802.3at PoE+ acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 2 % |
| Screen over stranding: | braiding |
| Screen over stranding element: | Foil |
| Separation class acc. EN50174-2: | D |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 10Gbit |
| UV resistant: | False |
Variants
| Item no. | Name | Colour outer sheath | Type | Number of cores | Length | Copper weight | Weight | Max. tractive force | Outer diameter approx. | Fire load | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 99988DX.100-CPR | INFRALAN Cat.7 1000 AWG23 S/FTP 2x4P CPR Cca orange 100m | orange | duplex | 2x8 | 100 m | 54 kg/km | 109 kg/km | 220 N | 7.3x15.0 mm | 1280 MJ/km | |
| 99988DX.500-CPR | INFRALAN Cat.7 1000 AWG23 S/FTP 2x4P CPR Cca orange 500m | orange | duplex | 2x8 | 500 m | 54 kg/km | 109 kg/km | 220 N | 7.3x15.0 mm | 1280 MJ/km |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range.
Manufacturer information
Draka Comteq Germany GmbH & Co. KG
Piccoloministraße 2
51063 Köln
kontakt@prysmian.com
https://de.prysmiangroup.com/