AWG-size: 26/7
Armour: none
Bending radius (dynamic): 40 mm
Bending radius (static): 20 mm
Cable: EN 50288-4-1 300, IEC 61156-6
Cable silicone free: True
Cable structure: F/UTP
Cable type: Draka UC300 S26
Cabling standards: EN 50173-1, ISO/IEC 11801
Category: 5e
Characteristic impedance: 100 ± 5 Ohm
Conductor category: Class 2 = stranded
Conductor material: Copper, tinned
Core identification: Colour
Core insulation: Polyethylene (PE)
Coupling attenuation: ≥ 55 dB
Delay skew: 20 ns/100m
Diameter conductor: 0.48 mm
Directive/Regulation: RoHS 2011/65/UE
Euro class: none
Flame retardant: acc. to EN 60332-1
Halogen free: acc. to EN 60754-1/2
Halogen free (acc. EN 50267-2-2): True
Harmonised Standard: EN 50575
Installation standard: EN 50174
Insulation resistance (500V): ≥ 2000 MOhm/km
Jacket material: FRNC-B
Loop resistance: 260 Ohm/km
Low smoke: acc. to EN 61034
Low smoke (acc. EN 61034-2): False
Max. frequency: MHz MHz
NVP value: 67 %
Nominal cross section conductor: 0.16 mm²
Operating capacity: 43 pF/km
Operating temperature, fix: -20 – 60 °C
Operating temperature, flexible: 0 – 50 °C
Operating temperature, storage: -20 – 60 °C
PoE: acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE
Resistance unbalance: 3 %
Screen over stranding: foil
Screen over stranding element: without
Stranding element: Pairs
Test voltage DC, 1 min: 1000 V
Transfer impedance at 1MHz: 50 mOhm/m
Transfer impedance at 10MHz: 100 mOhm/m
Transfer impedance at 30MHz: 200 mOhm/m
Transmission standards: IEEE 802.3 10Mbit bis 2.5Gbit
UV resistant: no

Technical properties

AWG-size: 26/7
Armour: none
Bending radius (dynamic): 40 mm
Bending radius (static): 20 mm
Cable: EN 50288-4-1 300, IEC 61156-6
Cable silicone free: True
Cable structure: F/UTP
Cable type: Draka UC300 S26
Cabling standards: EN 50173-1, ISO/IEC 11801
Category: 5e
Characteristic impedance: 100 ± 5 Ohm
Conductor category: Class 2 = stranded
Conductor material: Copper, tinned
Core identification: Colour
Core insulation: Polyethylene (PE)
Coupling attenuation: ≥ 55 dB
Delay skew: 20 ns/100m
Diameter conductor: 0.48 mm
Directive/Regulation: RoHS 2011/65/UE
Euro class: none
Flame retardant: acc. to EN 60332-1
Halogen free: acc. to EN 60754-1/2
Halogen free (acc. EN 50267-2-2): True
Harmonised Standard: EN 50575
Installation standard: EN 50174
Insulation resistance (500V): ≥ 2000 MOhm/km
Jacket material: FRNC-B
Loop resistance: 260 Ohm/km
Low smoke: acc. to EN 61034
Low smoke (acc. EN 61034-2): False
Max. frequency: MHz MHz
NVP value: 67 %
Nominal cross section conductor: 0.16 mm²
Operating capacity: 43 pF/km
Operating temperature, fix: -20 – 60 °C
Operating temperature, flexible: 0 – 50 °C
Operating temperature, storage: -20 – 60 °C
PoE: acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE
Resistance unbalance: 3 %
Screen over stranding: foil
Screen over stranding element: without
Stranding element: Pairs
Test voltage DC, 1 min: 1000 V
Transfer impedance at 1MHz: 50 mOhm/m
Transfer impedance at 10MHz: 100 mOhm/m
Transfer impedance at 30MHz: 200 mOhm/m
Transmission standards: IEEE 802.3 10Mbit bis 2.5Gbit
UV resistant: no

Variants

Item no. Name Length Type Number of cores Colour outer sheath Copper weight Weight Max. tractive force Outer diameter approx. Fire load
99153.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, green 1.0 m simplex 8 green 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99153.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, gren 1000.0 m simplex 8 green 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99154.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue 1.0 m simplex 8 blue 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99154.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue 1000.0 m simplex 8 blue 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99155.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow 1.0 m simplex 8 yellow 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99155.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow 1000.0 m simplex 8 yellow 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99156.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, red 1000.0 m simplex 8 red 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99157.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m 1.0 m simplex 8 black 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99157.100 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m 100.0 m simplex 8 black 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99157.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black 1000.0 m simplex 8 black 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99158.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey 1.0 m simplex 8 grey 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99158.100 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey,100m 100.0 m simplex 8 grey 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99158.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey 1000.0 m simplex 8 grey 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km

Product information for Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black

DRAKA Patch cable UC300 S26. Electrically and mechanically high-quality 300 MHz patch cable. Especially for application of class D.
AWG-size: 26/7
Armour: none
Bending radius (dynamic): 40 mm
Bending radius (static): 20 mm
Cable: EN 50288-4-1 300, IEC 61156-6
Cable silicone free: True
Cable structure: F/UTP
Cable type: Draka UC300 S26
Cabling standards: EN 50173-1, ISO/IEC 11801
Category: 5e
Characteristic impedance: 100 ± 5 Ohm
Conductor category: Class 2 = stranded
Conductor material: Copper, tinned
Core identification: Colour
Core insulation: Polyethylene (PE)
Coupling attenuation: ≥ 55 dB
Delay skew: 20 ns/100m
Diameter conductor: 0.48 mm
Directive/Regulation: RoHS 2011/65/UE
Euro class: none
Flame retardant: acc. to EN 60332-1
Halogen free: acc. to EN 60754-1/2
Halogen free (acc. EN 50267-2-2): True
Harmonised Standard: EN 50575
Installation standard: EN 50174
Insulation resistance (500V): ≥ 2000 MOhm/km
Jacket material: FRNC-B
Loop resistance: 260 Ohm/km
Low smoke: acc. to EN 61034
Low smoke (acc. EN 61034-2): False
Max. frequency: MHz MHz
NVP value: 67 %
Nominal cross section conductor: 0.16 mm²
Operating capacity: 43 pF/km
Operating temperature, fix: -20 – 60 °C
Operating temperature, flexible: 0 – 50 °C
Operating temperature, storage: -20 – 60 °C
PoE: acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE
Resistance unbalance: 3 %
Screen over stranding: foil
Screen over stranding element: without
Stranding element: Pairs
Test voltage DC, 1 min: 1000 V
Transfer impedance at 1MHz: 50 mOhm/m
Transfer impedance at 10MHz: 100 mOhm/m
Transfer impedance at 30MHz: 200 mOhm/m
Transmission standards: IEEE 802.3 10Mbit bis 2.5Gbit
UV resistant: no

AWG-size: 26/7
Armour: none
Bending radius (dynamic): 40 mm
Bending radius (static): 20 mm
Cable: EN 50288-4-1 300, IEC 61156-6
Cable silicone free: True
Cable structure: F/UTP
Cable type: Draka UC300 S26
Cabling standards: EN 50173-1, ISO/IEC 11801
Category: 5e
Characteristic impedance: 100 ± 5 Ohm
Conductor category: Class 2 = stranded
Conductor material: Copper, tinned
Core identification: Colour
Core insulation: Polyethylene (PE)
Coupling attenuation: ≥ 55 dB
Delay skew: 20 ns/100m
Diameter conductor: 0.48 mm
Directive/Regulation: RoHS 2011/65/UE
Euro class: none
Flame retardant: acc. to EN 60332-1
Halogen free: acc. to EN 60754-1/2
Halogen free (acc. EN 50267-2-2): True
Harmonised Standard: EN 50575
Installation standard: EN 50174
Insulation resistance (500V): ≥ 2000 MOhm/km
Jacket material: FRNC-B
Loop resistance: 260 Ohm/km
Low smoke: acc. to EN 61034
Low smoke (acc. EN 61034-2): False
Max. frequency: MHz MHz
NVP value: 67 %
Nominal cross section conductor: 0.16 mm²
Operating capacity: 43 pF/km
Operating temperature, fix: -20 – 60 °C
Operating temperature, flexible: 0 – 50 °C
Operating temperature, storage: -20 – 60 °C
PoE: acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE
Resistance unbalance: 3 %
Screen over stranding: foil
Screen over stranding element: without
Stranding element: Pairs
Test voltage DC, 1 min: 1000 V
Transfer impedance at 1MHz: 50 mOhm/m
Transfer impedance at 10MHz: 100 mOhm/m
Transfer impedance at 30MHz: 200 mOhm/m
Transmission standards: IEEE 802.3 10Mbit bis 2.5Gbit
UV resistant: no

Variants

Item no. Name Length Type Number of cores Colour outer sheath Copper weight Weight Max. tractive force Outer diameter approx. Fire load
99153.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, green 1.0 m simplex 8 green 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99153.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, gren 1000.0 m simplex 8 green 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99154.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue 1.0 m simplex 8 blue 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99154.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, blue 1000.0 m simplex 8 blue 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99155.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow 1.0 m simplex 8 yellow 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99155.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, yellow 1000.0 m simplex 8 yellow 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99156.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, red 1000.0 m simplex 8 red 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99157.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m 1.0 m simplex 8 black 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99157.100 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black,100m 100.0 m simplex 8 black 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99157.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, black 1000.0 m simplex 8 black 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99158.1 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey 1.0 m simplex 8 grey 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99158.100 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey,100m 100.0 m simplex 8 grey 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km
99158.1000 Patch C. Cat.5E Draka F/UTP AWG26, 300MHz, grey 1000.0 m simplex 8 grey 12 kg/km 26 kg/km 55 N 5.0 mm 354 MJ/km

Safety instructions


Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range.

Manufacturer information


Draka Comteq Germany GmbH & Co. KG
Piccoloministraße 2
51063 Köln
kontakt@prysmian.com
https://de.prysmiangroup.com/