INFRALAN® Cat.7A 1200 AWG22, S/FTP 2x4P CPR B2ca orange RAL 2003
Content:
1 Stück
INFRALAN® Cat.7A 1200 AWG22, S/FTP 2x4P CPR B2ca orange RAL 2003
Item number:
MK7100DX.500-CPR
EAN no.:
4049759180997
Product information for INFRALAN® Cat.7A 1200 AWG22, S/FTP 2x4P CPR B2ca orange RAL 2003
The INFRALAN Cat.7A installation cable S/FTP 1200 MHz with CPR B2ca is designed for high-performance network cabling. The S/FTP design with FRNC-B sheath supports stable data connections up to 1200 MHz and is therefore suitable for modern installations with high bandwidth.
• 1200 MHz Cat.7A bandwidth – Supports transmission standards from IEEE 802.3 10Mbit to 10Gbit and creates reserves for high-performance networks.
• S/FTP design with braid shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in orange with RAL 2003 and Euroclass B2ca – Complements the installation with a halogen-free material selection according to EN 60754-1/2 and RoHS 2011/65/UE.
The cable is designed as a duplex and uses 22/1 conductors with 2x8 wires. The dynamic bending radius of 40 mm facilitates installation. The braided shielding supports decoupling from external influences and the design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt. The version without reinforcement is aimed at laying in structured network environments.
Technical details
• Brand: INFRALAN
• Category: 7A
• Transmission standards: IEEE 802.3 10Mbit to 10Gbit
• Max. frequency: 1200 MHz
• Cable construction: S/FTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 22/1
• Number of cores: 2x8
• Type: duplex
• Sheath material: FRNC-B
• Sheath colour: orange
• RAL colour: RAL 2003
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: B2ca
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: braid
• 1200 MHz Cat.7A bandwidth – Supports transmission standards from IEEE 802.3 10Mbit to 10Gbit and creates reserves for high-performance networks.
• S/FTP design with braid shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in orange with RAL 2003 and Euroclass B2ca – Complements the installation with a halogen-free material selection according to EN 60754-1/2 and RoHS 2011/65/UE.
The cable is designed as a duplex and uses 22/1 conductors with 2x8 wires. The dynamic bending radius of 40 mm facilitates installation. The braided shielding supports decoupling from external influences and the design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt. The version without reinforcement is aimed at laying in structured network environments.
Technical details
• Brand: INFRALAN
• Category: 7A
• Transmission standards: IEEE 802.3 10Mbit to 10Gbit
• Max. frequency: 1200 MHz
• Cable construction: S/FTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 22/1
• Number of cores: 2x8
• Type: duplex
• Sheath material: FRNC-B
• Sheath colour: orange
• RAL colour: RAL 2003
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: B2ca
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: braid
| AWG-size: | 22/1 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 1200, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | S/FTP |
| Cable type: | EFB Cat.7A S/FTP 1200 AWG22 B2ca |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 7A |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 1 = solid |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Foam-Skin-PE |
| Coupling attenuation: | ≤ 85 dB |
| Diameter conductor: | 0.62 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | B2ca |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 143.4 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 78 % |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | -20 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | braiding |
| Screen over stranding element: | Foil |
| Separation class acc. EN50174-2: | D |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 10Gbit |
| UV resistant: | no |
Technical properties
| AWG-size: | 22/1 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 1200, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | S/FTP |
| Cable type: | EFB Cat.7A S/FTP 1200 AWG22 B2ca |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 7A |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 1 = solid |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Foam-Skin-PE |
| Coupling attenuation: | ≤ 85 dB |
| Diameter conductor: | 0.62 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | B2ca |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 143.4 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 78 % |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | -20 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | braiding |
| Screen over stranding element: | Foil |
| Separation class acc. EN50174-2: | D |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 10Gbit |
| UV resistant: | no |
Variants
| Item no. | Name | Colour outer sheath | RAL colour | Length | Type | Number of cores | Copper weight | Weight | Max. tractive force | Outer diameter approx. | Fire load | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MK7100.1-CPR | INFRALAN® Cat.7A 1200 AWG22, S/FTP 4P CPR B2ca orange RAL 2003 | orange | RAL 2003 | 1.0 m | simplex | 8 | 3.62 kg/km | 78 kg/km | 100 N | 8.4 mm | 640 MJ/km | |
| MK7100DX.500-CPR | INFRALAN® Cat.7A 1200 AWG22, S/FTP 2x4P CPR B2ca orange RAL 2003 | orange | RAL 2003 | 500.0 m | duplex | 2x8 | 7.24 kg/km | 156 kg/km | 100 N | 8.4 x16.8 mm | 1100 MJ/km |
Product information for INFRALAN® Cat.7A 1200 AWG22, S/FTP 2x4P CPR B2ca orange RAL 2003
The INFRALAN Cat.7A installation cable S/FTP 1200 MHz with CPR B2ca is designed for high-performance network cabling. The S/FTP design with FRNC-B sheath supports stable data connections up to 1200 MHz and is therefore suitable for modern installations with high bandwidth.
• 1200 MHz Cat.7A bandwidth – Supports transmission standards from IEEE 802.3 10Mbit to 10Gbit and creates reserves for high-performance networks.
• S/FTP design with braid shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in orange with RAL 2003 and Euroclass B2ca – Complements the installation with a halogen-free material selection according to EN 60754-1/2 and RoHS 2011/65/UE.
The cable is designed as a duplex and uses 22/1 conductors with 2x8 wires. The dynamic bending radius of 40 mm facilitates installation. The braided shielding supports decoupling from external influences and the design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt. The version without reinforcement is aimed at laying in structured network environments.
Technical details
• Brand: INFRALAN
• Category: 7A
• Transmission standards: IEEE 802.3 10Mbit to 10Gbit
• Max. frequency: 1200 MHz
• Cable construction: S/FTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 22/1
• Number of cores: 2x8
• Type: duplex
• Sheath material: FRNC-B
• Sheath colour: orange
• RAL colour: RAL 2003
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: B2ca
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: braid
• 1200 MHz Cat.7A bandwidth – Supports transmission standards from IEEE 802.3 10Mbit to 10Gbit and creates reserves for high-performance networks.
• S/FTP design with braid shielding – Reduces interference and supports stable signal quality in demanding cabling.
• FRNC-B jacket in orange with RAL 2003 and Euroclass B2ca – Complements the installation with a halogen-free material selection according to EN 60754-1/2 and RoHS 2011/65/UE.
The cable is designed as a duplex and uses 22/1 conductors with 2x8 wires. The dynamic bending radius of 40 mm facilitates installation. The braided shielding supports decoupling from external influences and the design is intended for PoE according to IEEE802.3af, PoE+ according to IEEE802.3at and 4PPoE according to IEEE802.3bt. The version without reinforcement is aimed at laying in structured network environments.
Technical details
• Brand: INFRALAN
• Category: 7A
• Transmission standards: IEEE 802.3 10Mbit to 10Gbit
• Max. frequency: 1200 MHz
• Cable construction: S/FTP
• PoE: after IEEE802.3af PoE, after IEEE802.3at PoE+, after IEEE802.3bt 4PPoE
• AWG cross-section/number of wires: 22/1
• Number of cores: 2x8
• Type: duplex
• Sheath material: FRNC-B
• Sheath colour: orange
• RAL colour: RAL 2003
• Armour: without
• Bend radius (dynamic): 40 mm
• Directive/Regulation: RoHS 2011/65/UE
• Euroclass: B2ca
• Halogen-free: according to EN 60754-1/2
• Shield over stranding: braid
| AWG-size: | 22/1 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 1200, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | S/FTP |
| Cable type: | EFB Cat.7A S/FTP 1200 AWG22 B2ca |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 7A |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 1 = solid |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Foam-Skin-PE |
| Coupling attenuation: | ≤ 85 dB |
| Diameter conductor: | 0.62 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | B2ca |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 143.4 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 78 % |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | -20 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | braiding |
| Screen over stranding element: | Foil |
| Separation class acc. EN50174-2: | D |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 10Gbit |
| UV resistant: | no |
| AWG-size: | 22/1 |
|---|---|
| Armour: | none |
| Bending radius (dynamic): | 40 mm |
| Cable: | EN 50288-4-1 1200, IEC 61156-6 |
| Cable silicone free: | True |
| Cable structure: | S/FTP |
| Cable type: | EFB Cat.7A S/FTP 1200 AWG22 B2ca |
| Cabling standards: | EN 50173-1, ISO/IEC 11801 |
| Category: | 7A |
| Characteristic impedance: | 100 ± 5 Ohm |
| Conductor category: | Class 1 = solid |
| Conductor material: | Copper, tinned |
| Core identification: | Colour |
| Core insulation: | Foam-Skin-PE |
| Coupling attenuation: | ≤ 85 dB |
| Diameter conductor: | 0.62 mm |
| Directive/Regulation: | RoHS 2011/65/UE |
| Euro class: | B2ca |
| Flame retardant: | acc. to EN 60332-1 |
| Halogen free: | acc. to EN 60754-1/2 |
| Harmonised Standard: | EN 50575 |
| Installation standard: | EN 50174 |
| Insulation resistance (500V): | ≥ 2000 MOhm/km |
| Loop resistance: | 143.4 Ohm/km |
| Low smoke: | acc. to EN 61034 |
| Material outer sheath: | FRNC-B |
| Max. Freuqency: | MHz MHz |
| NVP value: | 78 % |
| Operating capacity: | 43 pF/km |
| Operating temperature, fix: | -20 – 60 °C |
| Operating temperature, flexible: | -20 – 50 °C |
| Operating temperature, storage: | -20 – 60 °C |
| PoE: | acc. to IEEE802.3af PoE, acc. to IEEE802.3at PoE+, acc. to IEEE802.3bt 4PPoE |
| Resistance unbalance: | 3 % |
| Screen over stranding: | braiding |
| Screen over stranding element: | Foil |
| Separation class acc. EN50174-2: | D |
| Stranding element: | Pairs |
| Test voltage DC, 1 min: | 1000 V |
| Transmission standards: | IEEE 802.3 10Mbit bis 10Gbit |
| UV resistant: | no |
Variants
| Item no. | Name | Colour outer sheath | RAL colour | Length | Type | Number of cores | Copper weight | Weight | Max. tractive force | Outer diameter approx. | Fire load | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MK7100.1-CPR | INFRALAN® Cat.7A 1200 AWG22, S/FTP 4P CPR B2ca orange RAL 2003 | orange | RAL 2003 | 1.0 m | simplex | 8 | 3.62 kg/km | 78 kg/km | 100 N | 8.4 mm | 640 MJ/km | |
| MK7100DX.500-CPR | INFRALAN® Cat.7A 1200 AWG22, S/FTP 2x4P CPR B2ca orange RAL 2003 | orange | RAL 2003 | 500.0 m | duplex | 2x8 | 7.24 kg/km | 156 kg/km | 100 N | 8.4 x16.8 mm | 1100 MJ/km |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range.
Manufacturer information
EFB-Elektronik GmbH
Striegauer Str. 1
33719 Bielefeld
info@efb-elektronik.de
https://www.efb-elektronik.de