EFB Server, 600x1200, 1+2-Part Doors
Product information for 19" EFB Server 42U, 600x1200 mm, F=1-Part R=2-Part, RAL7035
Steel sheet housing with screwed profile frame, completely pre-assembled, dismountable
Inside front and rear 4 x 19“ profile rails (2 front, 2 rear), galvanised, toolless stepless depth-adjustable
Scaling for depth-adjustment at the profile carrying rails
Contrariwsie numbering of rack units at the 19“ profiles
Front- and rear door steel, perforated, 1-part or 2-part, perforation degree > 80 %, perforation area up to 86 %
1-part door with 5-point locking and turning handle, lockable, incl. profile half-cylinder acc. to DIN18252 / EN1303, door stop right or left-sided possible
2-part door with 3-point bar locking and turning handle, lockable, incl. profile half-cylinder acc. to DIN18252 / EN1303
Profile half-cylinder exchangeable by customer (30/10 mm)
Door opening angle up to 270°
Delivery without side walls, side walls available in 4 variants:
Type A – Side wall, horizontally divided, door opening angle 270°
Type B – Side wall, horizontally divided, enables lateral PDU mounting in cabinet width 600 mm
Type C – Bulkhead, 1-part, for cabinets with levelling feet
Type D – Bulkhead, 1-part, for cabinets without levelling feet
Cabinets stackable side-by-side with stacking set Art.-No. ESV-ANR01
Bulkheads are retrofittable onto already stacked cabinets
Roof toolless mountable, with pre-punched ventilation openings for use of up to 2 fan units (2-fan or 4-fan type)
Roof with cable entries over full cabinet length after toolless removal of the pre-punched lateral covers
Delivery without bottom
Max. load 1500 kg, optionally up to 2400 kg possible
All cabinet parts inside completely grounded
Paint finish RAL7035, light grey / RAL9005, jet black
Protection degree IP20 (except of bottom area)
Scope of supply: 1 x set of captive nuts (PU 20 pcs), 4 x levelling feet M12, 2 x key
Delivery in transport packaging on disposable pallet
Technical properties
| Active air conditioning: | False |
|---|---|
| Air inlet floor: | Bottom open when delivered, (modular floor panels optional) |
| Cabinet Series: | EFB-Server |
| Cable entry roof/floor: | Roof left and right across the entire depth of the cabinet, open base |
| Category: | 19" server cabinet according to DIN41494 |
| Degree of protection: | IP20 with base plates installed |
| Demountable: | True |
| Door hinge reversible front door: | True |
| Door hinge reversible rear door: | True |
| Door opening angle front door: | 270 ° |
| Door opening angle rear door: | 270 ° |
| Frame: | screwed together, completely pre-assembled |
| Material: | Steel |
| Model: | With permanent frame |
| Modular spacing: | 482.6 mm (19 inch) |
| Mounting level: | Front and rear |
| PHC replaceable front door: | True, according to DIN18252 (30/10 mm) |
| PHC replaceable rear door: | True |
| Packaging: | Delivery in transport packaging on a disposable pallet |
| Perforation level front door: | > 80 % / 86 % perforated area |
| Perforation level rear door: | > 80 % / 86 % perforated area |
| Scope of delivery: | 1x cabinet, 1 x cage nut set (20 pieces per pack), 4 x leveling feet M12, 2 x wrenches |
| Stackable: | True |
| Surface finishing: | powder coating |
| Toolless depth adjustment: | True |
| Type of back door: | Steel perforated 2-part |
| Type of front door: | Steel perforated 1-part |
| Type of profile rail: | Crank |
| Type of ventilation: | Passive |
| With backside door: | True |
| With earthing: | True |
| With front door: | True |
| With roof plate: | True |
| With sidewall: | No |
| With socket: | False |
Variants
| Item no. | Name | Number of height units | Color | Width | Material front door | Material rear door | Depth | Max. load capacity | With vertical cable management | With glazed door | Front door locking system | Rear door locking system | Height | RAL-number | Number of doors | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ESV-4262GR.P1P2OS | 19" EFB Server 42U, 600x1200 mm, F=1-Part R=2-Part, RAL7035 | 42 U | grey | 600 mm | Steel | Steel | 1200 mm | 1600 kg | False | False | 5-point rod locking mechanism with swivel lever | 3-point rod locking mechanism with swivel lever | 2000 mm | 7035 | 2 | |
| ESV-4762GR.P1P2OS | 19" EFB Server 47U, 600x1200 mm, F=1-Part R=2-Part, RAL7035 | 47 U | grey | 600 mm | Steel | Steel | 1200 mm | 1600 kg | False | False | 5-point rod locking mechanism with swivel lever | 3-point rod locking mechanism with swivel lever | 2200 mm | 7035 | 2 | |
| ESV-4262TS.P1P2OS | 19" EFB Server 42U, 600x1200 mm, F=1-Part R=2-Part, RAL9005 | 42 U | black | 600 mm | Steel | Steel | 1200 mm | 1600 kg | False | False | 5-point rod locking mechanism with swivel lever | 3-point rod locking mechanism with swivel lever | 2000 mm | 9005 | 2 | |
| ESV-4762TS.P1P2OS | 19" EFB Server 47U, 600x1200 mm, F=1-Part R=2-Part, RAL9005 | 47 U | black | 600 mm | Steel | Steel | 1200 mm | 1600 kg | False | False | 5-point rod locking mechanism with swivel lever | 3-point rod locking mechanism with swivel lever | 2200 mm | 9005 | 2 |
Safety instructions
Do not use the device if the cable or plug is damaged. This device may only be used in dry environments. Avoid faulty electrical connections. Only use the device within the specified voltage range. Do not block any ventilation openings to prevent components from overheating. Do not operate the appliance beyond the permissible connected loads to prevent overloading and excessive heat generation. Ensure that the device does not overheat during operation. Warning: Danger of electric shocks and short circuits! Ensure proper earthing to avoid electric shocks. Avoid overloading as this can lead to overheating and short circuits. Check that the housing is undamaged and that there are no exposed contacts or bare wires. Ensure that all electrical connections are made correctly and that the ambient conditions comply with the technical specifications. Always keep a sufficient distance from live devices and avoid misuse. Warning: Pay attention to the assembly sequence! Observe the correct assembly sequence, see instructions. Important safety information to prevent accidents and damage during installation: Hazard: If the raised floor is used incorrectly, it may break. Action: Avoid walking on the raised floor unless the correct loads and load specifications are taken into account. Incorrect loading Hazard: Incorrect loading can lead to instability and damage. Action: Ensure that the load is even and prescribed according to the manufacturer's instructions. Enclosure falls due to weight being exceeded Hazard: Exceeding the maximum weight limit can destabilize the enclosure. Action: Check the maximum permissible load of the enclosure and ensure that this is not exceeded. Falling components due to inadequate fastening Hazard: Inadequately fastened components can fall and cause injury. Action: Ensure that all parts are properly and securely assembled. Housing parts breaking out due to incorrect loading Danger: Inadmissible loading leads to material damage and possible housing parts breaking out. Action: Ensure that the load is distributed correctly and that the recommended load is used. Risk of tipping due to uneven floor Danger: An uneven floor can cause the cabinet or device to tip over. Action: Make sure that the surface is level and stable to avoid the risk of tipping. Risk of tipping due to insufficient load-bearing capacity of the surface Danger: Insufficient load-bearing capacity of the surface can encourage the cabinet to tip over. Action: Check the load-bearing capacity of the surface before installation and ensure that it can safely support the weight. Cabinet can tip over if heavy server unit is pulled forward Danger: Pulling heavy server units forward can cause the cabinet to tip over. Action: Always secure cabinets and server units with suitable brackets and seek assistance when handling heavy equipment. Risk of tipping over with heavy cooling unit without safety measures Hazard: Improper fastening of cooling units to external brackets can cause the cabinet or device to tip over. Action: Secure cooling units with suitable devices to prevent tipping. Side walls fall off - sash lock not used correctly Hazard: Incorrectly used sash locks can cause the side walls of the cabinet to fall off. Action: Regularly check that all sash locks are correctly and securely fitted. Load capacity not provided Hazard: An insufficient load capacity can destabilise the system. Action: Before installation, check the load capacity information and ensure that the base and the shelves are sufficiently stable. Inadequate fastening when fitting accessories Hazard: Loosely fitted accessories can fall down dangerously. Action: Fasten all accessories carefully and regularly check them for strength. Insufficient wall statics - housing falls down Danger: Insufficient wall statics can cause the housing to fall down. Action: Before installation, make sure that the wall has sufficient static load-bearing capacity and that the housing can be installed safely. Injury from falling attachments Danger: Insufficiently secured attachments can fall down and cause injuries. Action: Make sure that all attachments are correctly secured and check them regularly. Warning: Do not exceed the load capacity! If the specified load capacity is exceeded, serious injuries may occur due to instability of the product.
Manufacturer information